With the application of ¡°waterfall¡± effect,chenwu brand humidifier directly atomizes and evenly sprays water into space.the relative air humidity is thus increased and end breakage and electrostatic blocking effectively prcvented.it can fully meet the requirements of productive technology for air humidity. This device (patent No.ZL972124594,ZL97229056)collects fresh air through an extcrnao air passage to preyent fly occlusion.Therefore ,it is often used in a fly-rich workshop..

Alllication
¢Ù¡¢This product is used for partially or completely humidifying workshops in a textilc
factory such as cotton mill¡¢woolen mill¡¢flax mill¡¢silk mill and chemical fiber plant.
¢Ú¡¢Besides it can also be used in tobacco industry,tea proccssing industry,
gunpowder industry,paper industry,ect.
Working conditions
¢Ù¡¢Ambient temperature:0~40¡ãC
¢Ú¡¢Water:clean neutral tap water

1¡¢ Spray head
2¡¢ fan
3¡¢ mist collector
4¡¢ host machine
5¡¢ small motor
6¡¢ tunnel interface
7¡¢ gear ring
8¡¢ mist guide plate
9¡¢ water basin
10¡¢influent valve
11¡¢ adjusting screw
12¡¢ drainage slice
13¡¢ drainage thread plug
14¡¢ floating ball
15¡¢ water suction pipe
16¡¢ base of water wheel
17¡¢ water wheel
18¡¢ atomization net
19¡¢ ball
20¡¢ intermediate stand
21¡¢ splash ring
Clean, maintence and upkeep
A¡¢The humidifier should be cleaned when the mist output is found reducing. Remove the miscellany and dust attached on the nylon or metallic net on the outside of the wall first.Then clean the inside of the device (take RH-2 for example)
1¡¢ Cleaning the inside of humidifier, screw off the drainage thread plug (13) at the center of bottom, discharge the wastewater,
remove the drainage slice (12), clean the lower part of water suction pipe (15) and clean the water basin (9).
2¡¢ It should clean the fly waste on the mist net when the mist output is found largen. Take RH-2 for example, screw off the drainage
thread plug (13) at the center of bottom, remove the drainage slice (12), discharge the wastewater,and brush the fly waste on the
mist net (18) with brusher.
3¡¢ The way of clean inside of RH-3 humidifier is the same as RH-2.
B¡¢ The humidifier will not spray if the water level in the basin is too low due to low water pressure or low position of the water tower. In this case,adjust the adjusting screw (11) until a small amount of water flows out or the water level is 1cm lower than the lower part of the outlet.Anyway, if much water overflows or the water level is higher than the outlet, the machine must be stopped immediately, and adjust the water level reasonably, otherwise, themain motor may be burnt.
C¡¢ If the spray head does mot turn or turns interruptedly in RH-2 humidifier,then check whether the small motor (5) runs or not, and whether the ball
(19) turns or not.
Installation
A¡¢ The spray head of the humidifier can be turned by 360 ,and there are three kinds of installation method:
1¡¢ install on the crossbeam
2¡¢ put on the hathpace
3¡¢suspend under the roof
B¡¢ The connecting method of water inlet hose and overflow pipe: Connect the water inlet and delivery pipe after installing the
humidifier, turn on the water tap and put through the single-phase electrical source, then it can work .The water inlet and
overflow are connected through a plastic pipe or a G1/2¡± soft screwed conduit.The overflow pipe must be lower than overflow
outlet.Without water overflowing,the humidifier can also apray mist and the source water pressure also remains normal.Stop
the machineimmediately for inspection if there is much water overflow or the overflowed water level is higher than the outlet.
Turn off water source if the humidifier won£¬t be used for a long time.
C¡¢ The usage of humidity controller: If you want to humidify automatically,please put the humidity controller to a place where
the mist sprayed by the humidifier cannot reach directly, but also observe it easily, then put through the single-phase electrical
source. Connect the humidifier with humidity controller, and adjust the conteoller to the value as repuired by the workshop. When
the humidity gets to the preset value, the humidifier will turn off automatically. When the humidity drops under thej preset value,
the humidifier will start working automatically to keep proper humidity in the workshop.
D¡¢ The diagrammatic sketch for covering nylon net on the tunnel interface of humidifier air duct is not necessary in some workshop
s where the ambient air is clean enough such as chemical fiber industry and silk industry. In this case, it isjust enough to cover
nylon net on the tunnel interface. The nylon net will be put on a rectangular framework, which is installed at the tunnel interface.
The diagrammatic sketch is following, if the humidifier is used in a workshop where there is cotton, wool and linen etc. fly wastes,
you should note the following two points when connecting air-duct:
£±¡¢The part outside the wall should be made into a rectangular frameworkwhich is
covered with nylon or metallic net. The diagrammatic sketch is following.

2¡¢ The section area of the air duct should be not smaller than the tunnel interface£¬
s.The total section area of the air duct should be not smaller than all tunnel interface£¬
s when multi-installatino.



|